Join thousands of businesses already trading on AraBazaar, free forever. No commissions, no middlemen.
We are a powder coating manufacturer, and we supply epoxy insulation powders for parts that have to hold voltage. The series is made on epoxy resin and a…
Seller: Standard International Group (HK) Limited
Price: 2950.00 USD

PER TON
§ BULK ORDER
Competitive pricing · Dedicated account manager · Flexible delivery
We are a powder coating manufacturer, and we supply epoxy insulation powders for parts that have to hold voltage. The series is made on epoxy resin and a curing agent, and it covers stators and rotor cores, motor housings, busbars, capacitor shells, and transformer and control-cabinet parts, at the film thicknesses those windings and laminations actually need. Tell us the part, the voltage it has to withstand and the cure window your oven runs; we recommend the grade and send the quotation. Your line does the coating; we do the powder. Dielectric strength, temperature class, film thickness and cure schedule are matched to the component and to what it will see in service, not sold off a single headline figure. The data sheet and the test report for the grade being quoted are the documents that carry the numbers; this page explains how the grade behind them is chosen. Request Technical Datasheet Technical Overview Category Specifications Definition Thermosetting powder coatings designed to provide electrical insulation and protection for conductive components Key functions Prevent electrical leakage; withstand high voltages; protect against environmental factors Feature Property Typical Value Property Typical Value Granularity 100–200 μm ≥ 70%; 260 μm ≤ 0.5% External appearance Flat and smooth, slight orange peel allowed Edge coverage rate ≥ 30% Impact strength ≥ 50 kg·cm Adhesion (cross-cut) ≤ 2 grade Pencil hardness ≥ H Flexibility ≤ 3 mm Neutral salt spray No obvious change within 500 h Volume resistivity ≥ 1 × 10¹⁴ Ω·cm Electric intensity ≥ 30 kV/mm Cupping resistance ≥ 6 mm Damp heat resistance ≥ 1,000 h, slight gloss loss permitted Request Technical Datasheet Insulation Coating Families in the Market Type Dielectric Strength (kV/mm) Temperature Resistance (°C) Common Applications Epoxy-based 30–50 150–180 Transformers, bus bars Silicone-modified 20–40 200–250 High-temperature coils Polyester-imide 25–45 180–220 Motor windings, stators Fluoropolymer 15–30 250–300 Aerospace components Values are indicative ranges for the coating families sold in this market, not a stock list. The insulation series supplied on this page is epoxy-based; the silicone, polyester-imide and fluoropolymer rows are there for comparison, and any of those would be quoted against a separate grade and its own report. Key Electrical Properties Property Test Method Typical Value Dielectric Strength IEC 60243 ≥ 30 kV/mm Volume Resistivity IEC 60093 ≥ 10¹⁴ Ω·cm Arc Resistance ASTM D495 ≥ 180 sec Tracking Resistance IEC 60112 CTI ≥ 600 V Film density is what makes the electrical performance repeatable: a continuous, well-fused layer over the whole part keeps leakage paths closed. Thin spots at slot edges, pinholes over weld seams and under-cured patches are the usual causes of a failed hipot test, so edge coverage, film thickness and cure schedule should be controlled together rather than treated as separate settings. Application Process Step Parameters Equipment Surface preparation Degreasing, sandblasting Pretreatment line Powder application Electrostatic spray (40–80 kV) Spray booth Curing 160–200°C × 10–20 min Convection oven Quality control Thickness: 80–150 µm; Adhesion: Class 0 (ISO 2409) Coating analyzer Get a Grade Recommendation Field of Application The main use is on the stators and rotor cores of motors, where the slot walls and the lamination stack have to stay insulated from each other, including the rotors of automotive and motorcycle drives and of power tools. The powder coats the sharp edges of the slots to a consistent film thickness, so the insulation holds through the operating temperature and the vibration the part actually sees. Industry Applications Sector Components Key Requirements Power electronics Busbars, capacitors High dielectric strength Electric motors Stators, rotors Thermal + abrasion resistance Consumer electronics PCBs, heat sinks Thin-film insulation Renewable energy Solar inverters UV + moisture resistance Power distribution Transformer parts, control cabinets Dielectric strength at heavy film Powder vs Liquid Coating: Process Differences Feature Powder coating Liquid coating VOC emissions Zero (solvent-free system) Solvent-based systems emit VOC Edge coverage Measured edge coverage rate ≥ 30% (see Feature table) Edge build depends on spray passes Curing time 10–20 min at cure temperature Hours including flash-off and drying Waste reuse Overspray can be reclaimed and sieved Overspray cannot be reclaimed Practical note: the process numbers above are starting points, not a recipe for every part. Insulation parts are often thick, thermally heavy laminations, so oven air temperature is not the same as object temperature — check the part core reaches the cure window before the cycle ends, or the film stays under-cured and fails hipot. Masking has to be planned for bare contacts, threads and locating faces, and reclaimed powder should be sieved and blended within the manufacturer’s limit rather than run indefinitely. Trends in Insulation Coatings Trend Impact Low-temperature cure Enables coating of heat-sensitive substrates Enhanced thermal conductivity Improves heat dissipation while insulating Self-healing coatings Targets autonomous repair of minor cracks Halogen-free formulations Eco-friendly flame retardancy These are directions in the insulation coating market rather than a catalogue of stocked products; availability, performance data and compliance status for any of them should be confirmed with our technical team. Packing & Storage Item Specification Packing Double PP bags, N.W. 20 kg/carton Shelf life 12 months within 30°C, avoid direct sunlight Health and safety Refer to the MSDS. Request Quote & Specification Contact our team for electrical insulation powder specifications, dielectric and temperature class data, masking and cure guidance, and a quotation for your component program.