Join thousands of businesses already trading on AraBazaar, free forever. No commissions, no middlemen.
Product Description: The Agni Veiga Series Intelligent Isolator Module is a critical safety component designed for intelligent addressable fire alarm syst…
Seller: Agni Instruments Engineers India Private Limited
Price: 16.10 USD

PER PIECE
§ BULK ORDER
Competitive pricing · Dedicated account manager · Flexible delivery
The Agni Veiga Series Intelligent Isolator Module is a critical safety component designed for intelligent addressable fire alarm systems. It is used within Class A fire alarm loop circuits to help isolate a faulty section of the loop while allowing the remaining devices and communication paths to continue operating. The module uses the Veiga digital communication protocol for high-speed information exchange and supports bidirectional signal communication. In a Class A loop, the circuit starts at the fire alarm control panel, connects to the field devices, and returns to the panel, creating redundant signal paths. If a fault or cable break affects one path, communication can use the alternate path to maintain connectivity with the fire alarm control panel. Strategically installed at intervals along the loop, the Veiga Intelligent Isolator Module helps divide the circuit into protected sections. In the event of a short circuit or ground fault, the affected section can be isolated so that a single fault does not disable the entire loop. Once the fault condition is cleared, the isolator automatically restores the isolated section, helping minimize system downtime and maintenance effort. This makes the module particularly suitable for commercial, industrial, and institutional fire alarm installations where continuous monitoring, fault isolation, system reliability, and rapid emergency response are important. ________________________________________
________________________________________
1. Class A Redundant Loop The Class A loop starts at the fire alarm control panel, passes through connected field devices, and returns to the panel. This creates two potential signal paths. 2. Bidirectional Communication Signals can travel in both directions around the loop. If a cable break affects one path, communication can use the alternate path to reach the connected devices and fire alarm control panel. 3. Fault Isolation When a fault such as a short circuit affects a section of the loop, the isolator helps segment and isolate the affected portion. 4. Continued System Operation By isolating the problematic section, the remaining loop sections can continue communicating with the fire alarm control panel. 5. Automatic Restoration After the fault has been cleared, the isolator automatically restores the isolated section, reducing system downtime and maintenance requirements. ________________________________________
________________________________________
________________________________________
The redundant Class A loop architecture provides an alternate communication path when part of the circuit is affected.
The isolator helps prevent a single fault from disabling the entire addressable loop.
Signals can travel through either direction of the loop, helping maintain communication when a cable path is interrupted.
Once the fault is cleared, the affected section can automatically be restored.
Segmenting the loop with isolators helps maintenance personnel identify and manage problematic sections.
The design supports robust fire alarm communication in environments where continuous system availability is important. ________________________________________
The Veiga Intelligent Isolator Module is intended to be strategically installed at intervals within a Class A fire alarm loop. Segmenting the loop with isolators helps limit the impact of an individual fault and maintain communication with unaffected devices. For project-specific installation, wiring, spacing, compatibility, and system configuration, the manufacturer's applicable installation documentation and fire alarm system design requirements should be followed. ________________________________________
KEY HIGHLIGHTS
addressable isolator module circuit isolator fault isolator fault isolator module isolator module loop isolator module